CABO Safety Scalpel System
With CABO you'll get:
- to use your favourite scalpel handle
- clinical benefit of a polymer coated blade
- a sheath that fully retracts for a clear view of the blade
- easy load and unload
- safety without compromise
- OSHA compliance
![]() |
73-7010 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7210 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7011 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7211 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7015 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7215 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7016 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7216 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7020 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7220 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7021 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7221 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7022 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7222 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7024 | Sterile Disposable | 50/Box | 3 Boxes/Case | 150/Case |
| 73-7224 | Non-Sterile Disposable | 100/Box | 5 Boxes/Case | 500/Case | |
![]() |
73-7260 | Non-Sterile Disposable | 50/Box | 5 Boxes/Case | 250/Case |
Directions for Use

A - Saftey Sheath
B - Handle
C - Locking/Unlocking Mechanism
D - Polymer Coated Blade
E - Cartridge Thumb Release Mechanism
1. Cartridge Loading:
Grasp CABO Cartridge (A)
Firmly between thumb and
finger and insert scalpel
handle (B) into the open
slot of the CABO Cartridge, as found with typical blade
loading.
2. To Expose Blade:
Place thumb on top of safety sheath and push down on the locking/
unlocking mechanism (C). Continue pushing down on this mechanism and retract the sheath until the blade (D) is fully exposed and an audible click is heard, indicating that the sheath is locked in place and ready for use.
3. To Close Sheath:
Place thumb on top of safety sheath and push down on the locking/
unlocking mechanism (C). Continue pushing down on this mechanism and push the sheath forward until the blade is fully covered and an audible click is heard, indicating that the sheath is once again locked in placed and safe to pass or hand off.
4. Cartridge Unloading:
Position handle and cartridge on its side, so the Southmedic.com logo is
facing up. Place thumb
directly behind the release mechanism (E) (located at the rear of device) and push forward with a slight raising of the thumb. This will separate the device from the handle, allowing for a safe disposal of the soiled cartridge.